The degasser uses a woven fluoropolymer-monofilament mesh. Material grade, filament diameter and mesh construction are selected according to the condenser design and operating conditions.
For technical selection, provide the condenser drawing, gas and acid temperatures, sulfuric-acid concentration, gas flow, allowable pressure drop and required separation performance.